CPR-B6 Portable Ozone Tester is used to detect the ozone concentration in limited space and outside environment, and also can be used for sampling detection of ozone disinfected space. Tested gas contacts sensor in expanding mode and reacts, then outputs steady signal. The value of gas concentration can be digitally displayed on LCD. With audible and visual alarm, it can prevent harm to personnel from high concentration ozone. This product is widely used in pharmaceutical industry, hospital, food and beverage industry, refrigeration storage, agriculture, etc.
Features
Quick response time
Easy operation and steady performance
LCD display to read value straightly
Reliable quality and low maintenance
Audible and Visual Alarm, easy calibration
Small volume and easy to carry
Specification:
Tested Gas: Ozone (O3)
Model: CPR-B6-5 (Range: 0-5pppm; Resolution: 0.01ppm)
CFR-B6-100 (Range: 0-100ppm; Resolution: 0.1ppm)
Test Method: Extending type T90
Response Time: <60s
Accuracy: 1%F.S
Repeatability: ±2%F.S
Linearity: ±2%F.S
Temperature: -20℃~+50℃
Humidity: 0-95% without condensation
Alarm setting value: adjustable
Display: LCD digital display
Power: 9V Alkaline battery
Weight: 0.185kg
Dimension: 128×62×28(mm)
Accessories: carry case, calibration cap, battery, debugging tool
CPR-B6 Portable Ozone Tester is used to detect the ozone concentration in limited space and outside environment, and also can be used for sampling detection of ozone disinfected space. Tested gas contacts sensor in expanding mode and reacts, then outputs steady signal. The value of gas concentration can be digitally displayed on LCD. With audible and visual alarm, it can prevent harm to personnel from high concentration ozone. This product is widely used in pharmaceutical industry, hospital, food and beverage industry, refrigeration storage, agriculture, etc.
Features
Quick response time
Easy operation and steady performance
LCD display to read value straightly
Reliable quality and low maintenance
Audible and Visual Alarm, easy calibration
Small volume and easy to carry
Specification:
Tested Gas: Ozone (O3)
Model: CPR-B6-5 (Range: 0-5pppm; Resolution: 0.01ppm)
CFR-B6-100 (Range: 0-100ppm; Resolution: 0.1ppm)
Test Method: Extending type T90
Response Time: <60s
Accuracy: 1%F.S
Repeatability: ±2%F.S
Linearity: ±2%F.S
Temperature: -20℃~+50℃
Humidity: 0-95% without condensation
Alarm setting value: adjustable
Display: LCD digital display
Power: 9V Alkaline battery
Weight: 0.185kg
Dimension: 128×62×28(mm)
Accessories: carry case, calibration cap, battery, debugging tool